• 15kv Primary Ud Cable Trxlp Insulation
  • 15kv Primary Ud Cable Trxlp Insulation

15kv Primary Ud Cable Trxlp Insulation

Application: Underground
Voltage: Low and Medium Voltage Cable
Current: DC & AC
Insulation Material: XLPE
Sheath Material: PVC
Material Shape: Round Wire
Customization:

360° Virtual Tour

Diamond Member Since 2009

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
15kV UD cable BM19
Wire Core Material
Bare Copper Wire
Certification
ISO, CCC, CE, RoHS, UL, VDE
Model
YJV
Brand
Yifang
Conductor Option
Copper or Aluminum
Transport Package
Wooden or Wooden-Steel Drum
Specification
15kv UD cable
Trademark
Yifang Cable
Origin
Zhengzhou, China
HS Code
8544601200
Production Capacity
300km/Month

Product Description

Applications:
Predominantly used for primary underground distribution; suitable for use in wet or dry locations, direct burial, underground duct, and where exposed to sunlight. To be used at 15,000 volts or less and at conductor temperatures not to exceed 90°C for normal operation.

Specifications:
15kV HI-DRI Primary UD Cable meets or exceeds the following ASTM specifications:

  • B-3 Soft Annealed Copper Wire.
  • B-8 Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard or Soft.
  • B-230 Aluminum, 1350-H19 Wire for Electrical Purposes.
  • B-231 Aluminum 1350 Conductors, Concentric-Lay-Stranded.
  • B-609 Aluminum 1350 Round Wire, Annealed and Intermediate Tempers, for Electrical Purposes.

15kV HI-DRI Primary UD Cable is manufactured to the latest edition of the following specifications, and in case of specification conflicts, in the order listed:

  • ANSI/ICEA S-94-649
  • AEIC CS-8
  • RUS U-1

Construction:
The phase conductor is concentrically stranded, compressed soft copper or 1350-H16/26 aluminum alloy. The cable is composed of the conductor with moisture block in the strands, covered by a semi-conducting cross-linked polyethylene strand shield, a tree-retardant cross-linked polyethylene primary insulation, and a semi-conducting cross-linked polyethylene insulation shield. Conductors are available with either 100% or 133% insulation levels. A concentric neutral of bare copper wires and an insulating polyethylene jacket is applied over the insulation shield. The cable is identified by surface print on the jacket and with the lightning bolt symbol for supply cables indented in the jacket. A semi-conducting polyethylene jacket is available upon request.

 

EPR-PVC 15kV Grounded, Shielded Type MV90 Power Cable employs a Class B stranded copper conductor that bears ethylene propylene (EPR) rubber insulation and a polyvinyl chloride (PVC) external jacket.  The Class B stranded copper conductor is made of annealed uncoated copper.  Annealed copper is often preferred because the process softens the metal making it more flexible and maneuverable.  The assembly includes two separate layers of an extruded semi-conducting copolymer compound that serves as a shield over the conductors and over the insulation.  The extruded semi-conducting insulation shield is shielded with uncoated helically applied copper wires and then covered in 5 mil bare copper tape.  The outer PVC jacket protects the conductors from extreme temperatures, chemicals, and UV rays.

TECHNICAL PARAMETER LIST

 

Phase Conductor

Neutral

Thickness Per Cond. (mils)

Diameter (mils)

Weight

1000 feet

(lbs.)

Allowable

Ampacities+

Size (AWG or kcmil)

Strand- ing

No. of

Wires

Size

(AWG)

Nominal

Insul.

Insul. Shield min. Point

Approx. Jkt.

 

Bare Phase Cond.

Over

Insul.

 

Over Insul. Shield

Comp. Cable

Comp. Cable

Direct

Burial

In

Ducts

ALUMINUM CONDUCTOR - 100% INSULATION LEVEL

2

Solid

10

14

175

30

50

258

653

733

961

453

168*

119*

2

7

10

14

175

30

50

283

678

758

986

470

168*

119*

1

Solid

13

14

175

30

50

289

685

765

993

520

193*

137*

1

19

13

14

175

30

50

322

718

798

1026

539

193*

137*

1/0

Solid

16

14

175

30

50

325

720

800

1028

591

218*

155*

1/0

19

16

14

175

30

50

352

748

828

1056

609

218*

155*

2/0

19

20

14

175

30

50

395

790

870

1098

703

248*

177*

3/0

19

25

14

175

30

50

443

838

918

1146

817

284*

201*

4/0

19

20

12

175

30

50

498

893

973

1234

993

324*

230*

 250

37

16

10

175

30

50

558

963

1043

1346

1213

360*

257*

350

37

18

14

175

40

50

661

1068

1168

1396

1055

389**

319**

500

37

25

14

175

40

50

789

1193

1293

1521

1349

468**

384**

750

61

24

12

175

40

80

968

1383

1483

1798

1946

569**

468**

1000

61

20

10

175

40

80

1117

1530

1630

1988

2473

642**

542**

1250

91

25

10

220

55

80

1250

1765

1895

2253

3142

688**

604**

1500

91

30

10

220

55

80

1370

1885

2015

2373

3616

726**

637**

COPPER CONDUCTOR - 100% INSULATION LEVEL

2

Solid

16

14

175

30

50

258

653

733

961

664

210*

150*

2

7

16

14

175

30

50

283

678

758

986

684

210*

150*

1

Solid

20

14

175

30

50

289

685

765

993

780

240*

171*

1

19

20

14

175

30

50

322

718

798

1026

803

240*

171*

1/0

Solid

25

14

175

30

50

325

720

800

1028

922

273*

194*

1/0

19

25

14

175

30

50

362

758

838

1066

951

273*

194*

2/0

19

20

12

175

30

50

405

800

880

1142

1161

313*

224*

3/0

19

25

12

175

30

50

456

853

933

1194

1390

358*

255*

4/0

19

20

10

175

30

50

512

908

988

1291

1717

410*

293*

250

37

24

10

175

30

50

558

963

1043

1346

1992

446*

322*

350

37

18

12

175

40

50

661

1068

1168

1429

1964

489**

400**

500

37

26

12

175

40

50

789

1193

1293

1554

2651

577**

472**

750

61

25

10

175

40

80

968

1383

1483

1840

3906

649**

532**

1000

61

26

9

175

40

80

1117

1530

1630

2013

5041

720**

630**

1250

91

26

8

175

55

80

1250

1765

1895

2306

6400

760**

667**

+  Ampacities shown assume use of 100% load factor, 60 Hz current, 36" burial depth, 20°C ambient temperature, 90°C

conductor temperature, earth RHO 90, insulation and shield RHO 400

*   Full neutral construction (Ampacities assume - single phase circuit, one cable)

** 1/3 neutral cable (Ampacities assume - three phase circuit, 3 cables triplexed, multi-point grounding per ICEA methods)

 

EPR-PVC 15kV Grounded, Shielded Type MV90 Power Cable is designed to carry medium voltages up to 15,000 Volts.  These cables are intended for use as a feeder and can be used in many different types of applications. The cable can be installed in conduit, duct or aerial applications and must be supported by a messenger wire. This cable can also be buried directly, but only if it is installed in a system with a grounding conductor in close proximity.  The cable can function in wet or dry locations and has a maximum conductor temperature of 90°C.  This cable is acceptable by the Occupational Safety and Health Administration (OSHA) specifications.

15kv Primary Ud Cable Trxlp Insulation

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2009

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
122
Year of Establishment
2001-02-22