Customization: | Available |
---|---|
Application: | Construction, Underground, Industrial, Power Station |
Voltage: | Low and Medium Voltage Cable |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | Description | Application | |
Cu core | Al core | ||
YJV | YJLV | XLPE insulation PVC sheath power cable | To be laid indoors, in tunnel, cable furrow or pipe, the cable couldn't bear mechanical force outside |
YJY | YJLY | XLPE insulation PE sheath power cable | |
YJV22 | YJLV22 | XLPE insulation, steel tape armor, PVC sheath power cable | To be laid underground, the cable could bear certain mechanical force, but it couldn't bear great pulling force. |
YJV32 | YJLV32 | XLPE insulation, thin steel-wire armor, PVC sheath power cable | Be applicable to the well, water inside and fall in the bad soil, the cable cans bear the equal dint outside the machine with pull the dint |
YJV42 | YJLV42 | XLPE insulation, thick steel-wire armor, PVC sheath power cable | Be applicable to the well, underwater with the bottom of sea, the cable cans bear the bigger pressure with lead to pull the dint. |
Type |
No of Cores | Rated Voltage U( kV) |
33kV | ||
Conductor cross-section mm2 | ||
YJV YJV32(42) | 1 |
50-500 |
YJLV YJLV32(42) | 50-630 | |
YJV22 | ||
YJLV22 | ||
YJV YJV22 | 3 |
50-300 |
YJLV YJLV22 | 50-300 | |
YJV32 YJLV32 | 50-300 | |
YJV42 YJLV42 | 50-300 |
No.X Nominal Cross Section of Conductor | Nominal Diameter of Conductor | Nominal Thickness of Insulation | Nominal Thickness of Copper Tape Screen | Nominal Thickness of Inner Sheath | Nominal Thickness of Steel Tape Armouring | Nominal Thickness of PVC Sheath | Approx. Overall Diameter | Approx. Weight | |
Al Conductor | Cu Conductor | ||||||||
No. X mm2 | mm | mm | mm | mm | mm | mm | mm | kg/m | kg/m |
3 X 25 | |||||||||
3 X 35 | |||||||||
3 X50 | 8.2 | 8.0 | 0.1 | 1.7 | 0.5 | 2.8 | 70.4 | 4.56 | 5.41 |
3 X 70 | 9.7 | 8.0 | 0.1 | 1.7 | 0.5 | 2.9 | 73.9 | 5.04 | 6.26 |
3 X 95 | 11.3 | 8.0 | 0.1 | 1.8 | 0.5 | 3.0 | 77.7 | 5.62 | 7.32 |
3 X 120 | 12.8 | 8.0 | 0.1 | 1.9 | 0.8 | 3.2 | 82.8 | 6.99 | 9.15 |
3 X 150 | 14.2 | 8.0 | 0.1 | 1.9 | 0.8 | 3.2 | 85.8 | 7.56 | 10.26 |
3 X 185 | 15.9 | 8.0 | 0.1 | 2.0 | 0.8 | 3.3 | 89.9 | 8.30 | 11.67 |
3 X 240 | 18.3 | 8.0 | 0.1 | 2.1 | 0.8 | 3.5 | 95.7 | 9.36 | 13.79 |
3 X 300 | 20.4 | 8.0 | 0.1 | 2.2 | 0.8 | 3.6 | 100.6 | 10.51 | 16.07 |
3 X 400 | 23.2 | 8.0 | 0.1 | 2.3 | 0.8 | 3.8 | 107.2 | 11.99 | 19.07 |
3 X 500 | 26.4 | 8.0 | 0.1 | 2.4 | 0.8 | 4.0 | 120.1 | 14.15 | 23.85 |
Normal Cross Section of Conductor | Normal Diameter of Conductor | Normal Thickness of Insulation | Normal Thickness of Copper Tape |
Normal Thickness of Outer Sheath | Approx. Overall Dia. |
Approx. Net Weight | Max. D.C. Resistance of Conductor at 20°C | ||
Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | ||||||
mm2 | mm | mm | mm | mm | mm | kg/m | kg/m | Ω/km | Ω/km |
25 | |||||||||
35 | |||||||||
50 | 8.2 | 8.0 | 0.1 | 2.9 | 64.9 | 3.02 | 3.87 | 0.6410 | 0.4936 |
70 | 9.7 | 8.0 | 0.1 | 3.0 | 68.4 | 3.42 | 4.65 | 0.4430 | 0.3420 |
95 | 11.3 | 8.0 | 0.1 | 3.1 | 72.0 | 3.89 | 5.59 | 0.3200 | 0.2464 |
120 | 12.8 | 8.0 | 0.1 | 3.3 | 75.7 | 4.39 | 6.54 | 0.2530 | 0.1955 |
150 | 14.2 | 8.0 | 0.1 | 3.3 | 78.7 | 4.85 | 7.55 | 0.2060 | 0.1587 |
185 | 15.9 | 8.0 | 0.1 | 3.4 | 82.6 | 5.42 | 8.79 | 0.1640 | 0.1271 |
240 | 18.3 | 8.0 | 0.1 | 3.5 | 88.0 | 6.22 | 10.66 | 0.1250 | 0.0976 |
300 | 20.4 | 8.0 | 0.1 | 3.7 | 92.9 | 7.20 | 12.77 | 0.1000 | 0.0778 |
400 | 23.2 | 8.0 | 0.1 | 3.9 | 99.3 | 8.38 | 15.46 | 0.0778 | 0.0615 |
500 | 26.4 | 8.0 | 0.1 | 4.2 | 107.6 | 10.15 | 18.85 | 0.0605 | 0.0487 |