• Overhead Bare Conductor ACSR Rail
  • Overhead Bare Conductor ACSR Rail
  • Overhead Bare Conductor ACSR Rail
  • Overhead Bare Conductor ACSR Rail
  • Overhead Bare Conductor ACSR Rail
  • Overhead Bare Conductor ACSR Rail

Overhead Bare Conductor ACSR Rail

Application: Overhead, Power Station
Voltage: Super-high Voltage Cable
Current: DC Cable
Insulation Material: Bare
Material Shape: Round Wire
Wire Core Material: Aluminum
Samples:
US$ 0.01/Meter 1 Meter(Min.Order)
| Request Sample
Customization:

360° Virtual Tour

Diamond Member Since 2009

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
ACSR Conductor
Certification
ISO, CCC, CE
Model
AAC
Brand
Yifang
Transport Package
Wooden Drum, Steel-Wooden Drum, Steel Reel
Trademark
Yifang
Origin
China
Production Capacity
50000ton/Month

Product Description

Overhead Bare Conductor ACSR RAIL


Productor description:

1.Aluminum conductor and Alumum Alloy Conductor 
(1). All aluminium conductor (AAC) 
(2). All aluminimum alloy conductor(AAAC) 
(3). Aluminum conductor steel reinforced (ACSR) 
(4). Anti-corrosion type ACSR 
(5). Aluminimum conductor aluminimum clad steel reinforced(ACSR/AW) 
(6). Rear earth aluminimum conductor steel reinforced(ACSR/RE) 
(7). Aluminimum conductor aluminimum alloy reinforced(ACAR) 

2. Elative manufacturing standards: IEC83, IEC1089, 31, B232, BS215, DIN48204. 
1). Standard: IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182. 
2). Specification: ACSR is composed by bare concentric-lay-stranded galvanized steel wire(s) with aluminum wires surrounded by one or more layers of helically. Greased ACSR can also be supplied. 
3). Application: ACSR is widely used in overhead electric power transmission and distribution lines with various voltage levels. 

All Aluminum Conductor(AAC)& Aluminum Conductor Steel Reinforced(ACSR))for ASTM (AAC, ACCR, AAAC, ACSR) Generally Confirming to IS 398 (Part-I, II, IV), IEC-228 
(AAAC) Conductor as per ASTM-B-399-1992 
(AAAC) Conductor as per BS-3242-1970 
(AAAC) Conductor IS: 398-IV-1994 
(ACSR) as per ASTM-B-233-1992 
(AAC) as per BS-215-1-1970 
(AAC) as per IS-398-1: 1976 
(AAC) as per ASTM-B-231-1990 
(ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992 
(ACSR) BS-215-II-1970 
(AACSR) as per IEC-1089-1191 

AAC(All aluminum conductor) are suited for overhead power line. 

We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, STM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied. 

ACSR or ACSR cable or ACSR conductor used for Overhead electrical distribution and transmission lines for distributing power. 

Applications: 
Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity. 

Construction: 
Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; ""aluminized"" aluminum coated (AZ); Or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corer or infusion of the complete cable with grease. 

Specifications: 
ACSR bare conductor meets or exceeds the following ASTM specifications: 
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes 
B-231 Aluminum Conductors, Concentric-Lay-Stranded 
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR) 
B-341 Aluminum-clad Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW) 
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ) 
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR) 

Notes: 
Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions. 
Current ratings are based on 75oC conductor temperature, 25oC ambient, 2ft/s wind, 96/watts/sq. Ft sun, 0.5 coefficients of emissivity and absorption.

What are Aluminium Conductors used for?

Aluminium Conductors are predominantly used in Overhead Line applications and for primary and secondary power distribution. 

The higher strength ACSR conductors are used for river crossings, overhead earth wires, and installations involving extra long spans. The advantage of ACSR is that it has high tensile strength and is lightweight, which means over longer spans it needs less supports. ACSR is available with varying percentages of steel core to achieve different strengths. One of the advantages of this conductor in particular is that the desired strength can be achieved without a loss of ampacity. 

AAC is used mainly in urban areas where the spacing is short and the supports are closer together. The advantage of AAC conductors is that they have a high degree of corrosion resistance; for this reason they are used extensively in coastal areas. AAC Conductors were developed as a consequence of the galvanic corrosion that ACSR conductors are susceptible to. 

AAAC is used as bare overhead conductor for power transmission and distribution lines on aerial circuits that require larger mechanical resistance than AAC. AAAC also has better sag characteristics and a better strength to weight ratio than AAC. AAAC Cables have lower weight per unit length and slightly lower resistance per unit length than ACSR.

What is the difference between ACSR, AAC and AAAC Conductors?

The biggest difference between AAC, AAAC, and ACSR conductors are the materials they are constructed from. AAC is manufactured from electrolytically refined aluminium with a 99.7% minimum purity, AAAC is made from an Aluminium alloy, and ACSR contains a combination of Aluminium reinforced with Steel. 

The second factor that differentiates the three cables is their resistance to corrosion, which is important for the longevity of the cable. ACSR has a poorer resistance to corrosion, as it contains steel, which is prone to rust. AAAC and AAC have a better corrosion resistance, due to the fact that they are largely or completely aluminium. 

In an ACSR the galvanised steel core carries the mechanical load and the high purity aluminium carries the current. These utilise the lower thermal expansion coefficient of steel compared to aluminium, which the aluminium based conductors AAC and AAAC are unable to do.

What do ACSR, AAC and AAAC Conductors have in common?

ACSR, AAC and AAAC are all used in overhead line applications, and although for different specific applications, they are all involved in power distribution.

 Bare conductors are designed and manufactured according to customer's special request .

Overhead Bare Conductor ACSR RailOverhead Bare Conductor ACSR RailOur company

Yifang Electric group mainly specialized in wire&cables,including designment,production and sale.

Products are mainly covering low,medium,high voltage(1KV to 220KV) XLPE Insulated power cable,PVC insulated power cable,ABC cable,building cable control cable,rubber cable welding cable Etc.

Our XLPE cable can be manufactured according to the company's specification which is equivalent to IEC 60502,IEC60332,IEC60754. Some indexes are superior to above international standard.


Overhead Bare Conductor ACSR Rail
Our certificate

Overhead Bare Conductor ACSR Rail

FAQ
1.Q:Are you a factory or trading company? 
 A: Manufacturing base in Henan ,China, with more than 500 workers.

2.Q:How can I visit there? 
 A: Sure,If you need,we will arrange the driver to pick you up. 

3.Q:How can I get some samples? 
 A: Contact me on below,Determin sample and address for shipping.  

4.Q:Have you ever supplied cables to our country? 
 A: Yifang Cables have been sold to over 100 countries and regions in the world. can you contact me for details.

5.Q:What is your MOQ? 
A: MOQ Normally 500 meters for big diameter cables.Please contact me for detail info if you have specific cable requirement. 

6. Q:When can I get the price? 
A: Usually quote within 6 hours after we get your inquiry. 

7.Q:How long is your delivery time?
 A: According to your order's quantity.Usually our lead time is 3 - 20 working days.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2009

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
122
Year of Establishment
2001-02-22