Customization: | Available |
---|---|
Type: | Bare |
Conductor Type: | Stranded |
Still deciding? Get samples of US$ 0/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Bare Conductor wire
1. Introduction
Bare conductor is an electrical conductor having no covering or electrical insulation. Some types of bare conductors include AAC, AAAC, ACSR, AACSR and ACAR etc.
2. Applications
Used as bare overhead transmission cable and as primary and secondary distribution cable.
ACSR offers optimal strength for line design.
Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.
AAC Conductor are constructed with a straight round central aluminum wire surrounded by one or more layers of helically laid aluminium wires.
The most commonly used stranding consists of 7, 19, 37, 61 and 91 wires.
In all constructions, the successive layers shall have opposite directions of lay, the outermost layer being right-handed.
Designed utilizing a high-strength aluminum-alloy to achieve a high strength-to-weight ratio; affords good sag characteristics.
Aluminum-alloy gives 6201-T81 gives AAAC higher resistance to corrosion than ACSR.
3. Specifications
ACSR
Bare ACSR conductors meet or exceed the following ASTM specifications:
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
B-341 Aluminum Coated (Aluminized) Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-498 Zinc Coated Steel (Galvanized) Core Wire for Aluminum Conductors, Steel Reinforced (ACSR)
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR)
AAC
AAC bare conductors meet or exceed the following ASTM specifications:
B-230 Aluminum Wire, 1350-H119 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-400 Compact Round Concentric-Lay-Stranded Aluminum 1350 Conductors
AAAC
AAAC bare conductor meets or exceeds the following ASTM specifications:
B-398 Aluminum Alloy 6201-T81 Wire for Electrical Purposes
B-399 Concentric-Lay-Stranded 6201 J81 Aluminum Alloy Conductors
ACSR Technical Characteristics Based on Standard BS 215-2
Code name |
Nominal aluminium area |
Stranding and wire diameter |
Sectional area of aluminium |
Total sectional area |
Approx. overall diameter |
Approx. mass |
Calculated D.C. resistance at 20oC |
Calculated breaking load |
|
Al |
Steel |
||||||||
mm2 |
No./mm |
mm2 |
mm2 |
mm |
kg/km |
Ω/km |
kN |
||
RABBIT |
50 |
6/3.35 |
1/3.35 |
52.88 |
61.7 |
10.05 |
214 |
0.5426 |
18.35 |
DOG |
100 |
6/4.72 |
7/1.57 |
105 |
118.5 |
14.15 |
394 |
0.2733 |
32.7 |
WOLF |
150 |
30/2.59 |
7/2.59 |
158.1 |
194.9 |
18.13 |
726 |
0.1828 |
69.2 |
DINGO |
150 |
18/3.35 |
1/3.35 |
158.7 |
167.5 |
16.75 |
506 |
0.1815 |
35.7 |
LYNX |
175 |
30/2.79 |
7/2.79 |
183.4 |
226.2 |
19.53 |
842 |
0.1576 |
79.8 |
ZEBRA |
400 |
54/3.18 |
7/3.18 |
428.9 |
484.5 |
28.62 |
1621 |
0.0674 |
131.9 |
AAC Technical Characteristics Based on Standard DIN 48201 / DIN EN50182
Code number |
Area |
Number of wires |
Wire diameter |
Conductor diameter |
Linear mass |
Rated strength |
D.C. resistance at 20oC |
mm2 |
No. |
mm |
mm |
kg/km |
kN |
Ω/km |
|
16 |
15.9 |
7 |
1.7 |
5.1 |
43.4 |
3.02 |
1.7986 |
25 |
24.2 |
7 |
2.1 |
6.3 |
66.3 |
4.36 |
1.1787 |
35 |
34.4 |
7 |
2.5 |
7.5 |
93.9 |
6.01 |
0.8317 |
50 |
49.5 |
7 |
3 |
9 |
135.2 |
8.41 |
0.5776 |
50 |
48.3 |
19 |
1.8 |
9 |
132.9 |
8.94 |
0.5944 |
70 |
65.8 |
19 |
2.1 |
10.5 |
180.9 |
11.85 |
0.4367 |
95 |
93.3 |
19 |
2.5 |
12.5 |
256.3 |
16.32 |
0.3081 |
120 |
117 |
19 |
2.8 |
14 |
321.5 |
19.89 |
0.2456 |
150 |
147.1 |
37 |
2.25 |
15.8 |
405.7 |
26.48 |
0.196 |
185 |
181.6 |
37 |
2.5 |
17.5 |
500.9 |
31.78 |
0.1588 |
240 |
242.5 |
61 |
2.25 |
20.3 |
671.1 |
43.66 |
0.1193 |
300 |
299.4 |
61 |
2.5 |
22.5 |
828.5 |
52.4 |
0.0966 |
AAAC Technical Characteristics Based on Standard BS 3242
Code name |
Nominal aluminium area |
Stranding and wire diameter |
Sectional area |
Approx. overall diameter |
Approx. mass |
Calculated D.C. resistance at 20oC |
Calculated breaking load |
mm2 |
No./mm |
mm2 |
mm |
kg/km |
Ω/km |
kN |
|
ALMOND |
25 |
7/2.34 |
30.1 |
7.02 |
82 |
1.094 |
8.44 |
CEDAR |
30 |
7/2.54 |
35.47 |
7.62 |
97 |
0.9281 |
9.94 |
FIR |
40 |
7/2.95 |
47.84 |
8.85 |
131 |
0.688 |
13.4 |
HAZEL |
50 |
7/3.30 |
59.87 |
9.9 |
164 |
0.5498 |
16.8 |
OAK |
100 |
7/4.65 |
118.9 |
13.95 |
325 |
0.2769 |
33.3 |
ASH |
150 |
19/3.48 |
180.7 |
17.4 |
497 |
0.183 |
50.65 |
ELM |
175 |
19/3.76 |
211 |
18.8 |
580 |
0.1568 |
59.1 |
UPAS |
300 |
37/3.53 |
362.1 |
24.71 |
997 |
0.09155 |
101.5 |
About us
Zhengzhou Yifang Cable Co., Ltd is a large joint-stock, hi-tech enterprise established in 2001. We are specialized in wires & cables, including designment, production and sales. Located in Zhengzhou, China, our factory's position is extremely advantageous.
There are more than 500 staffs in our factory including over 50 technical personnel, 5 senior engineers. With complete advanced cable producing equipments over 150 sets, complete testing equipments, a national level fire-resistant & flame retardant cable laboratory. Our technology has reached advanced levels at home and abroad.
Our main products include: Power Cable for voltage up to 220KV, Overhead insulated cable, ABC Cable, Building Cable and flexible cord, Control Cable, Rubber Cable, Bare Conductor(ACSR, AAC, AAAC, BCC), Welding Cable, Galvanized Steel Wire(Stay wire),flame retardant mining cable, etc
We have own IM/EX right, our products have been exported to Europe, Australian, Middle-east, South-east Asia, Africa, American, South American etc., being subjected to consistent good opinion of customers.