Customization: | Available |
---|---|
Type: | Insulated |
Conductor Type: | Stranded |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
H07RN-F Cable Construction:
H07RN-F Cable Technical Data:
H07RN-F Cable Ratings & Approvals:
Working temperature:
H07RN-F model rated voltage U0/U IS 450/750V
H05RN-F model rated voltage U0/U IS 300/500V
H05RR-F model rated voltage U0/U IS 300/500V
Long time allow working temperature of wire core cant be higher than 60C
HAR Code | IEC | Description | Voltage Design | Cores |
H05RR-F | 60245IEC 53(YZ)/YZ | Ordinary rubber sheathed cord | 300/500V | 2~6 |
H05RN-F | 60245 IEC 57(YZW)/YZW | Ordinary polychloroprene or other equivalent synthetic elastomer sheathed cord | 300/500V | 2~6 |
H07RN-F | 60245 IEC 66(YCW)/YC | Heavy polychloroprene or other equivalent synthetic elastomer sheathed flexible cable | 450/750V | 1~5, 3+1/3+2/4+1 |
H01N2-D | 60245 IEC 81(YH) | Rubber sheathed arc-welding electrode cable | 100/100V | 10-120 |
60245 IEC 82(YHF) |
polychloroprene or other equivalent synthetic elastomer sheathed arc-welding electrode cable | 100/100V | 10-120 |
The Product Model & Specification
Core no. x Nominal sectional area (mm2) |
Pcs./Wire dia. (mm) |
Insulation thickness(mm) |
Sheath thickness (mm) |
Average outer dia.(mm) |
Weight Reference kg/km |
Max DC resistance of conductor at20°C Ω/km |
|
Min. |
Max. |
||||||
1×1.5 |
30/0.25 |
0.8 |
1.4 |
5.7 |
7.1 |
76 |
13.3 |
1×2.5 |
49/0.25 |
0.9 |
1.4 |
6.3 |
7.9 |
98 |
7.98 |
1×4 |
56/0.30 |
1.0 |
1.5 |
7.2 |
9.0 |
130 |
4.95 |
1×6 |
84/0.30 |
1.0 |
1.6 |
7.9 |
9.8 |
174 |
3.30 |
1×10 |
84/0.40 |
1.2 |
1.8 |
9.5 |
11.9 |
251 |
1.91 |
1×16 |
126/0.40 |
1.2 |
1.9 |
10.8 |
13.4 |
330 |
1.21 |
1×25 |
196/0.40 |
1.4 |
2.0 |
12.7 |
15.8 |
475 |
0.780 |
1×35 |
276/0.40 |
1.4 |
2.2 |
14.3 |
17.9 |
605 |
0.554 |
1×50 |
396/0.40 |
1.6 |
2.4 |
16.5 |
20.6 |
828 |
0.386 |