50mm2 AAC Ant Conductor for Overhead Use

Product Details
Customization: Available
Type: Bare
Conductor Type: Stranded
Still deciding? Get samples of $ !
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Industry-leading Audited Factory

Diamond Member Since 2009

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Patents Awarded
The supplier had awarded 1 patents, you can check the Audit Report for more information
Standardized quality control
The supplier has a complete and standardized quality control process, check the Audit Report for more information
to see all verified strength labels (29)
  • 50mm2 AAC Ant Conductor for Overhead Use
  • 50mm2 AAC Ant Conductor for Overhead Use
  • 50mm2 AAC Ant Conductor for Overhead Use
  • 50mm2 AAC Ant Conductor for Overhead Use
  • 50mm2 AAC Ant Conductor for Overhead Use
  • 50mm2 AAC Ant Conductor for Overhead Use
Find Similar Products

Basic Info.

Model NO.
AAC
Application
Overhead
Conductor Material
Aluminum
Insulation Material
Bare
Certification
ISO9001
Product Name
AWG AAC Aluminum Wires Stranding Conductor
Temperature Range
-40-90°c
Surface States
Smooth
Standards and Specifications
IEC 61089,GB/T 1179-2017,ASTM B232 ACSR
Transport Package
Wooden Drums or Reels or as Your Request
Specification
DIN48, BS215, IEC 61089
Trademark
Yifang
Origin
Henan, China
HS Code
761490000
Production Capacity
200, 000 Kilometers Per Month

Product Description

AAC(All Aluminium Conductor)
All Aluminum Conductor(AAC)& Aluminum Conductor Steel Reinforced(ACSR)for ASTM: IEC61089, IEC209, IEC888, IEC889, EN50182, ASTM
All Aluminum Conductor(AAC)& Aluminum Conductor Steel Reinforced(ACSR))for ASTM (AAC, ACCR, AAAC, ACSR) Generally Confirming to IS 398 (Part-I, II, IV), IEC-228
(AAAC) Conductor as per ASTM-B-399-1992
(AAAC) Conductor as per BS-3242-1970
(AAAC) Conductor IS: 398-IV-1994
(ACSR) as per ASTM-B-233-1992
(AAC) as per BS-215-1-1970
(AAC) as per IS-398-1: 1976
(AAC) as per ASTM-B-231-1990
(ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992
(ACSR) BS-215-II-1970
(AACSR) as per IEC-1089-1191
Detailed Product Description
AAC(All aluminum conductor) are suited for overhead power line.
We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, STM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.
Other Popular Sizes BS EN 50182: 2001

Code name Gnat Mosquito Ladybird Bluebottle Earwig Grasshopper Clegg Beetle
ACSR or ACSR cable or ACSR conductor used for Overhead electrical distribution and transmission lines for distributing power
Applications
Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.

Construction
Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; ""aluminized"" aluminum coated (AZ); Or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corer or infusion of the complete cable with grease.

Specifications
ACSR bare conductor meets or exceeds the following ASTM specifications:

B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
B-341 Aluminum-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR)

Notes
1) Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions.
2) Current ratings are based on 75oC conductor temperature, 25oC ambient, 2ft/s wind, 96/watts/sq. Ft sun, 0.5 coefficients of emissivity and absorption.

Code Name Code Name Code Name Code Name High Strength strandings
Turkey Ibis Egret Curlew Grouse
Swan Lark Flamingo Bluejay Petrel
Swanate Pelican Gannet Finch Minorca
Sparrow Flicker Stilt Bunting Leghorn
Sparate Hawk Starling Grackle Guinea
Robin Hen Redwing Bittern Dotterel
Raven Osprey Tern Pheasant Dorking
Quail Parakeet Condor Dipper Cochin
Pigeon Dove Cuckoo Martin Brahma
Penguin Eagle Drake Bobolink
Waxwing Peacock Mallard Plover
Partridge Squab Ruddy Nuthatch
Ostrich Wood Duck Canary Parrot
Linnet Teal Rail Lapwing
Oriole Kingbird Cardinal Falcon
Chickadee Rook Ortlan Chukar
Brant Grosbeak
No. Description   Offered
       
1 Standard of Manufacture   BS 215
       
      Suitable  for  continous  outdoor  in  tropical
2 Service Conditions   Climate with Maximumambient temperature
      of +40 ºC,heavy polluting saline conditions
       
      and Humidity of up to 95%.
3 Nominal conductor area (mm2) 50
4 Number & size of wires (No./ mm2) 7/3.10
5 Nominal overall diameter (mm) bare 9.30
     
6 Max.d.c resistance at 20ºC(ohm/km) 0.5419
     
7 Minimum breaking load (kN) 8.28
     
8 Approx. Mass of conductor 145
  - Bare (kg/km)    
       
9 Conductor Drawing    
     
10 Packing Length (m) per drum 5000±5%

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier