Cu/Al Conductor XLPE Insulation SWA(steel wire armor)PVC Sheath Power Cable
4x95mm2
1. The applications: Rated voltage (U0/U) 0.6/1KV in transmission & transformation line & for water-proofing purpose .
2. Standards: IEC60502-1 2004 ISO9001:2008
3. Product Features:
1) No necessary to heat up in advance while installing above 0oC.
2) Max. continuous normal operating Temperature: 70oC (PVC Sheathed Cable).
3) Max. Permissible temperature at short circuit (5s. at longest): 250oC.
4) Permissible bending radius:
Single core: ≥20(d+D)±5%.
Three-core:≥15(d+D)±5%(D is the actual overall diameter of cable, and d is the actual overall diameter of conductor).
Detailed Description
Cross-linked XLPE insulation power cable not only has excellent electric and mechanical properties, but also has powerful resistance against chemical corrosion, heat-aging and environmental stress. Its structure is simple and can be used conveniently and also can be laid with no restriction of different levels. The long term operating temperature is 900C, and its transmission capacitance is large.
Our company can produce both flame retardant and non-flame retardant series of XLPE power cables. Our products can be produced according to our works specifications which are equivalent to GB12706, IEC60502, IEC60332, IEC60754, and its some indexes are superior to standards as stated above..
The flame-retardant cable covers all kinds of low-smoke, free-halogen, low-smoke halogen free and three classes of A, B, C. We can design and manufacture special XLPE cables according to the other standards require by the customers, such as heavy section cut part conductors, water-resistant, defend termites, defend mouse, and so on.
Type |
Description |
Main Application |
Cu core |
Al core |
(ZR)YJV
or
(ZR)YJY |
(ZR)YJLV
or
(ZR)YJLY23 |
(Flame retardant) Cu, Al core XLPE insulated, PVC or PE sheathed power cable. |
For laying indoor, tunnel, underground and canal. Unable to bear external mechanical pulling force and pressure during laid. |
(ZR)YJV22
or
(ZR)YJY23 |
(ZR)YJLV22
or
(ZR)YJLV23 |
(Flame retardant) Cu, Al core XLPE insulated, steel armoured, PVC or PE sheathed power cable. |
For laying indoor, tunnel, underground and canal. Able to bear external mechanical pulling force , but unable to bear large pulling force. |
(ZR)YJLV32
or
(ZR)YJLV33 |
(ZR)YJLV32
or
(ZR)YJLV33 |
(Flame retardant) Cu, Al core XLPE insulated, fine steel wire armoured, PVC or PE sheathed power cable |
For laying in shaft, water under ground and large difference of level, able to bear mechanical pressure and moderate pulling force. |
(ZR)YJLV42
or
(ZR)YJLV43 |
(ZR)YJLV42
or
(ZR)YJLV43 |
(Flame retardant) Cu, Al core XLPE insulated, thick steel wire armoured, PVC or PE sheathed power cable |
For laying in the water, seabed and large difference of level, able to bear large mechanical pressure and pulling force. |
The Rated Voltage, No of Core and Range of sectional Area
Rate Voltage(kv):
1st class 0.6/1kV 1.8/3kV 3.6/6kV 6/10kV 8.7/15kV 12/20kV 18/30kV 21/35kV
2nd class 1/1kV 3/3kV 6/6kV 8.7/10kV 12/15kV 18/20kV 26/35kV
No. Of Core and Sectional Area(mm2) :
1 Core 1.5-800 25-800 25-1200 25-1200 35-1200 50-1200 50-1200 50-1200
2 Core 1.5-185 25-185
3 Core 1.5-400 25-400 25-400 25-400 35-400 50-400 50-400 50-400
4 Core 2.5-400 25-400
5 Core 2.5-400 25-400