33kv 1 Core 500mm2 Swa South Africa Standard Sans 1339 Mv Power Cable

Product Details
Customization: Available
Application: Construction, Underground, Power Station
Voltage: Low and Medium Voltage Cable
Still deciding? Get samples of US$ 0.1/Meter
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2009

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Patents Awarded
The supplier had awarded 1 patents, you can check the Audit Report for more information
Standardized quality control
The supplier has a complete and standardized quality control process, check the Audit Report for more information
to see all verified strength labels (29)
  • 33kv 1 Core 500mm2 Swa South Africa Standard Sans 1339 Mv Power Cable
  • 33kv 1 Core 500mm2 Swa South Africa Standard Sans 1339 Mv Power Cable
  • 33kv 1 Core 500mm2 Swa South Africa Standard Sans 1339 Mv Power Cable
  • 33kv 1 Core 500mm2 Swa South Africa Standard Sans 1339 Mv Power Cable
  • 33kv 1 Core 500mm2 Swa South Africa Standard Sans 1339 Mv Power Cable
  • 33kv 1 Core 500mm2 Swa South Africa Standard Sans 1339 Mv Power Cable
Find Similar Products
  • Overview
  • Detailed Photos
  • Our Advantages
  • Packaging & Shipping
  • Company Profile
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
Mv Cable
Current
AC Cable
Insulation Material
XLPE
Sheath Material
PVC
Material Shape
Round Wire
Wire Core Material
Bare Copper Wire
Certification
ISO, CCC
Model
YJV
Brand
Yifang Cable
Transport Package
Steel-Wooden Drum Packing
Specification
90mm2 150mm2 185mm2 240mm2 300mm2
Trademark
YIFANG
Origin
China
HS Code
8544601200

Product Description

Structure 
Conductor: Solid or stranded copper/Aluminum
Insulation: Cross-linked polyethylene (XLPE) or Polyvinyl chloride (PVC)
Filler: Polypropylene filament with lapped binding tape
Binder: Binding tape
Inner sheath: Polyvinyl chloride (PVC)
Armouring: Single Core: AWA (Aluminium Wire Armour)
                   Multi Core:   SWA (Steel Wire Armour)  STA (Steel Tape Armour)
Sheath: Polyvinyl chloride (PVC)

 Application
1,Long term working temperature for the cable with PVC insulated is 70ºC;
Long term working temperature for the cable with XLPE insulated is 90ºC
2,Short circuit temperature
For PVC insulated cable ,the highest conductor temperature is not more than160ºC.(lasting time not over 5 seconds).
For XLPE insulated cable ,the highest conductor temperature is not more than250ºC.(Lasting time is not over 5 seconds).
3,Laying temperature not less than 0ºC and the drop height is out of consideration.
4,The cable with chemical stability, anti- acid, anti-alkali, anti-oil, anti-organic solvent, not easy to be burning.
5,Easy for installation, easy bending and light.

Operating characteristics
- Rated power-frepuency voltage U0/U: 3.6/6kv~26/35kv.
- Max.admissible operating temperature of the conductor:90ºC.
- Max. short-circurt temperature of conductor shall not exceed 2500C. (5s maximum duration)
- The ambient temperature under installation should not below 00C.
- The bending radius of a single-core cable should not less than 20 times of the cable diameter. 
The bending radius of a multi-core cable should not less than 15 times of the cable diameter. 

Table of the voltage, cores and cross-section
Item Category    A ,B 3.6/6kV 6/10kV 8.7/15kV 12/20kV 18/30kV 21/35kV
Category    A ,B 6/6kV 8.7/10kV 12/15kV 18/20kV - 26/35kV
Single core mm2 25-1200 25-1200 35-1200 50-1200 50-1200 50-1200
Three core mm2 25-400 25-400 35-400 50-400 50-400 50-400

The cable with Category A rated voltage is used in the situation requiring not over 1 min. of grounding fault lasting time. For the cable with Category B rated voltage, the grounding fault lasting time normally is not over 1 hour, max. lasting time is not over 8 hours, annual ground fault lasting time altogether should not be over 125 hours, Category C includes all the system expect Category A and B.
5 Type and Name
Type Designation Applications
YJV Copper conductor,XLPE insulated,PVC sheathed power cable For laying indoors,in tunnel or cable trench,unable to bear external mechanical forces.Single core cable is not allowed to laid in magnetic duct.
YJLV Aluminum conductor,XLPE insulated,PVC sheathed power cable
YJY Copper conductor, XLPE insulated,PE sheathed power cable
YJLY Aluminum conductor, XLPE insulated,PE sheathed power cable
YJV22 Copper conductor,XLPE insulated,steel tape armoured,PVC sheathed power cable For laying indoors,in tunnel in cable trench,or direct in ground,able to bear external mechanical forces.Single core cable is not allowed to laid in magnetic duct.
YJLV22 Aluminum conductor,XLPE insulated,steel tape armoured,PVC sheathed power cable
YJV23 Copper conductor,XLPE insulated,steel tape armoured,PE sheathed power cable
YJLV23 Aluminum conductor,XLPE insulated,steel tape armoured,PE sheathed power cable
YJV32 Copper conductor,XLPE insulated,steel wire armoured,PVC sheathed power cable For laying indoors,in tunnel cable trench,well or direct in ground,able to bear external mechanical forces and certain pulling force.
YJLV32 Aluminum conductor,XLPE insulated,steel wire armoured,PVC sheathed power cable
YJV33 Copper conductor,XLPE insulated,steel wire armoured,PE sheathed power cable
YJLV33 Aluminum conductor,XLPE insulated,steel wire armoured,PE sheathed power cable
Product Pictures
 33kv 1 Core 500mm2 Swa South Africa Standard Sans 1339 Mv Power Cable33kv 1 Core 500mm2 Swa South Africa Standard Sans 1339 Mv Power Cable
 

Detailed Photos

33kv 1 Core 500mm2 Swa South Africa Standard Sans 1339 Mv Power Cable
33kv 1 Core 500mm2 Swa South Africa Standard Sans 1339 Mv Power Cable
33kv 1 Core 500mm2 Swa South Africa Standard Sans 1339 Mv Power Cable
33kv 1 Core 500mm2 Swa South Africa Standard Sans 1339 Mv Power Cable
33kv 1 Core 500mm2 Swa South Africa Standard Sans 1339 Mv Power Cable
33kv 1 Core 500mm2 Swa South Africa Standard Sans 1339 Mv Power Cable
33kv 1 Core 500mm2 Swa South Africa Standard Sans 1339 Mv Power Cable
33kv 1 Core 500mm2 Swa South Africa Standard Sans 1339 Mv Power Cable

 

Our Advantages

33kv 1 Core 500mm2 Swa South Africa Standard Sans 1339 Mv Power Cable
33kv 1 Core 500mm2 Swa South Africa Standard Sans 1339 Mv Power Cable33kv 1 Core 500mm2 Swa South Africa Standard Sans 1339 Mv Power Cable

Packaging & Shipping

33kv 1 Core 500mm2 Swa South Africa Standard Sans 1339 Mv Power Cable

33kv 1 Core 500mm2 Swa South Africa Standard Sans 1339 Mv Power Cable
33kv 1 Core 500mm2 Swa South Africa Standard Sans 1339 Mv Power Cable
33kv 1 Core 500mm2 Swa South Africa Standard Sans 1339 Mv Power Cable
 

Company Profile

Yifang Electric Group Inc. mainly specialized in wires&cables, including designment, production and sale.


Products are mainly covering low,medium,high voltage(1KV to 220KV) XLPE Insulated power cable,PVC insulated power cable,ABC cable,building cable control cable,rubber cable welding cable Etc.

Our XLPE cable can be manufactured according to the company's specification which is equivalent to IEC 60502,IEC60332,IEC60754. Some indexes are superior to above international standard.

33kv 1 Core 500mm2 Swa South Africa Standard Sans 1339 Mv Power Cable

Certifications

 

33kv 1 Core 500mm2 Swa South Africa Standard Sans 1339 Mv Power Cable33kv 1 Core 500mm2 Swa South Africa Standard Sans 1339 Mv Power Cable

FAQ

1.Q:Are you a factory or trading company? 

 A: Manufacturing base in Henan ,China, with more than 500 workers.

2.Q:How can I visit there? 
 A: Sure,If you need,we will arrange the driver to pick you up. 

3.Q:How can I get some samples? 
 A: Contact me on below,Determin sample and address for shipping.  

4.Q:Have you ever supplied cables to our country? 
 A: Yifang Cables have been sold to over 100 countries and regions in the world. can you contact me for details.

5.Q:What is your MOQ? 
A: MOQ Normally 500 meters for big diameter cables.Please contact me for detail info if you have specific cable requirement. 

6. Q:When can I get the price? 
A: Usually quote within 6 hours after we get your inquiry. 

7.Q:How long is your delivery time?
 A: According to your order's quantity.Usually our lead time is 3 - 20 working days.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier