The three core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 3.6/6.6KV to 19/33KV and frequency 50Hz.
They are suitable for installation mostly in power supply stations, indoors and in cable ducts, outdoors, underground and in water as well as for installation on cable trays for industries, switchboards and power stations.
| onductor | Plain annealed copper or aluminium complying with IEC 60228/BS 6360. Copper conductors shall be stranded (class 2) and aluminium conductors shall be either solid or stranded (class 2). |
| Conductor Screen | Extruded layer of semi-conducting cross-linkable compound is applied over the conductor and shall cover the surface completely. The minimum thickness is 0.3mm and the maximum resistivity shall not exceed 500 Ohm-m at 90°C. |
| Insulation | Insulation is of cross-linked polyethylene compound XLPE (GP8) conforming to BS 7655-1.3 or EPR (GP7), conforming to BS 7655-1.2. |
| Nom. Cross Section Area | Insulation Thickness at Nominal Voltage | ||||
|---|---|---|---|---|---|
| 3.8/6.6KV (Um=7.2KV) | 6.35/11KV (Um=12KV) | 8.7/15KV (Um=17.5KV) | 12.7/22KV (Um=24KV) | 19/33KV (Um=36KV) | |
| mm^2 | mm | mm | mm | mm | mm |
| 70 - 185 | 2.5 | 3.4 | 4.5 | 5.5 | 8.0 |
| 240 | 2.6 | 3.4 | 4.5 | 5.5 | 8.0 |
| 300 | 2.8 | 3.4 | 4.5 | 5.5 | 8.0 |
| 400 | 3.0 | 3.4 | 4.5 | 5.5 | 8.0 |
| Above 500 | 3.2 | 3.4 | 4.5 | 5.5 | 8.0 |
| Insulaton Screen | Extruded layer of semi-conducting cross-linkable compound is applied over the insulation. The extruded semi-conducting layer shall consist of bonded or cold strippable semi-conducting compound capable of removal for jointing or terminating. As an option, a semi-conducting tape may be applied over the extruded semi-conducting layer as a bedding for the metallic layer. The minimum thickness is 0.3 mm and the maximum resistivity is 500 Ohm-m at 90°C. The screen is tightly fitted to the insulation to exclude all air voids and can be easily hand stripped on site. |
| Inner Covering & Fillers | For cables with a collective metallic layer or cables with a metallic layer over each individual cores with additional collective metallic layers, semi-conducting inner covering and fillers shall be applied over the laid up cores. The inner covering is made of non hygroscopic material, except if the cable is to be made longitudinally watertight. The inner covering shall be extruded or lapped. |
The approximate thickness of extruded inner coverings is given in Table 2:
| Ficititous Diameter over Laid Up Cores | Approx. Thickress of Extruded Inner Covering | |
|---|---|---|
| mm | mm | |
| > | < | |
| 35 | 45 | 1.0 |
| 25 | 35 | 1.2 |
| 35 | 45 | 1.4 |
| 45 | 60 | 1.6 |
| 60 | 80 | 1.8 |
| 80 | - | 2.0 |
*The approximate thickness of lapped inner coverings shall be 0.6mm.
| Metallic Layer | The metallic layer shall be applied over each core or applied as a collective screen. The metallic screen shall consist of either copper tapes or a concentric layer of copper wires or a combination of tapes and wires. The metallic layer provides an earth fault current path, capable of withstanding fault current to earth of 1000A for one second at maximum temperature 160°C. Copper wires are applied over the conducting water blocking layer with a minimum diameter of 0.5mm. And over the copper wires, copper tape with minimum thickness of 0.1mm can be applied helically with overlap. |
Total cross section of copper wire screen is shown in table 3:
| Nominal Cross-Section Area of Cable | Minimum Cross-Section of Copper Wire Screen Area | DC Resistance of the Copper Wire Screen |
|---|---|---|
| mm^2 | mm^2 | mm |
| up to 120 | 16 | 1.06 |
| 150-300 | 25 | 0.72 |
| 400-630 | 35 | 0.51 |
| Separation Sheath (for armoured cable) | The separation sheath comprises a layer of extruded PVC, PE or LSZH. The nominal thickness is calculated by 0.02Du + 0.6mm where Du is the fictitious diameter under the sheath in mm. The nominal separation sheath thickness shall not be less than 1.2mm. |
| Armour (for armoured cable) | The armour consists of galvanized steel wire applied over the inner covering with diameter specified as in Table 4. |
| Fictitiious Diameter under the Armour | Armour Wire Diameter | |
|---|---|---|
| mm | mm | |
| > | < | |
| 25 | 1.6 | |
| 25 | 35 | 2.0 |
| 35 | 60 | 2.5 |
| 60 | - | 3.15 |
| Over Sheath | Overall sheath comprises a layer of extruded either PVC type 9 conforming to BS 7665-4.2 or MDPE type TS2 conforming to BS 7655-10.1; LSZH can be offered as an option. The over sheath is normally black in colour. When a DC voltage test is to be performed on the over sheath, a semi-conducting layer such as graphite coating shall be applied over the surface of the extruded over sheath. The nominal over sheath thickness is calculated by 0.035+D where D is the diameter immediately under the over sheath in mm. For cables with the over sheath not applied over the armour, the nominal over sheath thickness shall not be less than 1.4mm. And for cables with over sheath applied over the armour, the nominal over sheath thickness shall not be less than 1.8mm. |
| Operating Temperature | up to 90°C |
| Temperature Range | -5°C ( PVC or LSZH sheath ); -20°C ( PE sheath ) |
| Short Circuit Temperature | 250°C (short circuit duration up to 5 seconds) |
| Bending Radius | 15 x OD |
| Rated Voltage Uo/U | Operating Voltage (Um) | Testing Voltage (rms) |
|---|---|---|
| 3.8/6.6KV | 7.2KV | 15KV |
| 6.35/11KV | 12KV | 25.5KV |
| 8.7/15KV | 17.5KV | 35KV |
| 12.7/22KV | 24KV | 51KV |
| 19/33KV | 36KV | 76KV |
Established in 2001, Yifang Electric Group Inc. is a leading, hi-tech, large joint-stock enterprise specializing in the design, production, and sales of (wires & cables) in China. Based in Zhengzhou, the factory enjoys a strategic location with more than 500 employees, including 50+ technical staff and 5 senior engineers. Our facility boasts over 150 sets of advanced cable production equipment and complete testing facilities, including a state-of-the-art national-level fire-resistant and flame-retardant cable laboratory.
We manufacture a wide range of high-quality products, including power cables up to 220KV, overhead insulated cables, ABC cables, building cables, flexible cords, control cables, rubber cables, bare conductors (ACSR, AAC, AAAC), welding cables, galvanized steel wire (stay wire), flame retardant mining cables, and more. As an export-import company, we have exported our products to Europe, Australia, the Middle East, Southeast Asia, Africa, the Americas, and beyond. Our commitments to customer satisfaction and quality have earned us extensive praise from customers worldwide.
While maintaining ISO9001, ISO14001, and OHSAS18001 certifications, as well as CCC, CE, and IEC international certificates, we have passed audits by SGS and BV. We believe in fostering a people-oriented environment, promoting comprehensive quality management systems, and collaborating with individuals from various social sectors in a journey of shared prosperity.





1.Q:Are you a factory or trading company?
A: Manufacturing base in Henan ,China, with more than 500 workers.
2.Q:How can I visit there?
A: Sure,If you need,we will arrange the driver to pick you up.
3.Q:How can I get some samples?
A: Contact me on below,Determin sample and address for shipping.
4.Q:Have you ever supplied cables to our country?
A: Yifang Cables have been sold to over 100 countries and regions in the world. can you contact me for details.
5.Q:What is your MOQ?
A: MOQ Normally 500 meters for big diameter cables.Please contact me for detail info if you have specific cable requirement.
6. Q:When can I get the price?
A: Usually quote within 6 hours after we get your inquiry.
7.Q:How long is your delivery time?
A: According to your order's quantity.Usually our lead time is 3 - 20 working days.