Copper Conductor Mv18/30kv XLPE Armor Power Cabe

Product Details
Customization: Available
Application: Construction, Underground
Voltage: Low and Medium Voltage Cable
Manufacturer/Factory & Trading Company

360° Virtual Tour

Industry-leading Audited Factory

Diamond Member Since 2009

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Patents Awarded
The supplier had awarded 1 patents, you can check the Audit Report for more information
Standardized quality control
The supplier has a complete and standardized quality control process, check the Audit Report for more information
to see all verified strength labels (29)
  • Copper Conductor Mv18/30kv XLPE Armor Power Cabe
  • Copper Conductor Mv18/30kv XLPE Armor Power Cabe
  • Copper Conductor Mv18/30kv XLPE Armor Power Cabe
  • Copper Conductor Mv18/30kv XLPE Armor Power Cabe
  • Copper Conductor Mv18/30kv XLPE Armor Power Cabe
  • Copper Conductor Mv18/30kv XLPE Armor Power Cabe
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
Overview

Basic Info.

Current
DC & AC
Insulation Material
XLPE
Sheath Material
PVC or PE
Material Shape
Round Wire
Wire Core Material
Bare Copper Wire
Certification
ISO, CCC, CE, RoHS, VDE
Model
Yjv32 Yjlv32 Yjsv32 Yjsv 72 Yjlv32 Yjlsv32
Brand
Yifang
Option Conductor
Aluminum
Transport Package
Wooden or Wooden-Steel Drum
Specification
single core & multicores
Trademark
Yifang Cable
Origin
Zhengzhou, China
HS Code
8544601200
Production Capacity
300km/Month

Product Description

Applications
Medium-Voltage power cables offer an economical, rugged and reliable alternative to labor-intensive cable in conduit wiring methods.
Installed on metal racks, troughs, in raceways, in cable trays or secured to supports spaced not more than six feet apart.
Installed in both exposed and concealed work, wet or dry locations, directly buried.

Construction
Conductor: Class B Compressed concentric strand or soft drawn annealed copper per ASTM B3. 
Conductor Shield: Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation
Insulation: Extruded, Tree-Retardant Cross-linked Polyethylene (TRXLPE) as defined in ANSI/ICEA S-94-649
Insulation Shield: Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. 
Metallic Shield: The metallic shield is flat uncoated 5-mil thick copper tape helically applied with minimum 20% overlap. A Mylar ribbon is longitudinally applied under the copper tape shield for phase identification - 1C w/Red, 1C w/Blue, and 1C w/None. 
Grounding Conductors: Three bare stranded copper conductor, one in each interstice. 
Fillers: Non hydroscopic fillers, forming a firm and cylindrical cable core. 
Binder Tape: A binder tape is applied to maintain core symmetry and mechanical stability. 
Jacket: Black, sunlight resistant, flame retardant PVC jacket tightly applied over the binder tape. 

Standards

  • AEIC CS8, Specifications for Shielded Power Cable, 5-46kV
  • ICEA S-93-639, 5-46 kV Shielded Power Cable
  • ICEA S-97-682, Utility Shielded Power Cable Rated 5-46 kV
  • UL 1072 MV-105
  • IEEE- IEEE 383 Flame Test
  • For 105°C continuous, 140°C emergency, 250°C short-circuit operation.
  • CSA Standard C68.5-07 File # 257759 Primary Shielded and Concentric Neutral Cable for Distribution
 

NOTES: 

Ampacities are based on three Phase Operation

In Duct (2011 NEC Table 310.15(B)(80): Three-conductor cable in plastic duct, direct-buried, 90°C conductor temperature, 20°C ambient temperature, earth RHO of 90°C-cm/Watt, and 100% load factor, and shields short-circuited.

Isolated in Air (2011 NEC Table 310.15(B)(72)): Three-conductor cable, 90°C conductor temperature, and 40°C ambient temperature, and shields grounded at one point only.

In Cable Tray: Per 2011 NEC 392.80(B)(1)(b), for single conductor cables, sizes 1/0 AWG and larger, installed in a single layer in an uncovered table tray, with a maintained space of not less than one cable diameter between individual conductors, the ampacities shall not exceed the allowable ampacities stated in 2011 NEC Table 310.15(B)(72) (Aluminum), "Isolated in Air" values noted above.

Product Description
Rated Voltage (kV) 3.6/6 6/6 6/10 8.7/10 8.7/15 12/15 12/20 18/20 18/30 21/35 26/35
Core Number 1Core       3Core
Cross- section
mm2
1C 25~800 35~800
3C 25~400 35~400

b) ASTM standard
Rated Voltage (V) 5001-8000 8001-15000 15001-25000 25001-28000 28001-35000 35000-46000
Core Number 1Core 3Core
Cross-section
AWG or kcmil
1C 6AWG~1600kcmil 2AWG~1600kcmil 1AWG~1600kcmil 2AWG~1600kcmil 1/0AWG~1600kcmil
3C 6AWG~1600kcmil 2AWG~1600kcmil 1AWG~1600kcmil 2AWG~1600kcmil 4/0AWG~1600kcmil