BS215 Bare Conductor ACSR Dog Rabbit Conductor
1. ACSR Conductor standard available such as IEC61089, BS215, CSA 61089, ASTM B-232, DIN 48204, etc.
2. ACSR Conductor is widely used in power transmission lines with various voltage levels. It has good characteristics such as simple structure, convenient installation and maintenance, low cost for the line, large transmission capacity and are also suitable for laying across rivers and valleys where special geographical textures exist.
3. ACSR consists of a galvanized steel core of 1 wire, 7 wires or 19 wires surrounded by concentric layers of aluminium wire. When a conductor with a high current carrying capacity and comparatively low strength is required, special constructions are available with a high aluminium content.
4. Protection against Corrosion (Optional)
Grease can be used to the steel core. One or more layers of the aluminium wires can, if required, be supplied partially or fully greased.
5. Certificate available: ISO, CE, SGS, SONCAP, BV, COC etc
For further information, pls contact us.
AAC Technical Characteristics Based on Standard DIN 48201 / DIN EN50182
Code number |
Area |
Number of wires |
Wire diameter |
Conductor diameter |
Linear mass |
Rated strength |
D.C. resistance at 20oC |
mm2 |
No. |
mm |
mm |
kg/km |
kN |
Ω/km |
16 |
15.9 |
7 |
1.7 |
5.1 |
43.4 |
3.02 |
1.7986 |
25 |
24.2 |
7 |
2.1 |
6.3 |
66.3 |
4.36 |
1.1787 |
35 |
34.4 |
7 |
2.5 |
7.5 |
93.9 |
6.01 |
0.8317 |
50 |
49.5 |
7 |
3 |
9 |
135.2 |
8.41 |
0.5776 |
50 |
48.3 |
19 |
1.8 |
9 |
132.9 |
8.94 |
0.5944 |
70 |
65.8 |
19 |
2.1 |
10.5 |
180.9 |
11.85 |
0.4367 |
95 |
93.3 |
19 |
2.5 |
12.5 |
256.3 |
16.32 |
0.3081 |
120 |
117 |
19 |
2.8 |
14 |
321.5 |
19.89 |
0.2456 |
150 |
147.1 |
37 |
2.25 |
15.8 |
405.7 |
26.48 |
0.196 |
185 |
181.6 |
37 |
2.5 |
17.5 |
500.9 |
31.78 |
0.1588 |
240 |
242.5 |
61 |
2.25 |
20.3 |
671.1 |
43.66 |
0.1193 |
300 |
299.4 |
61 |
2.5 |
22.5 |
828.5 |
52.4 |
0.0966 |
ACSR Technical Characteristics Based on Standard BS 215-2
Code name |
Nominal aluminium area |
Stranding and wire diameter |
Sectional area of aluminium |
Total sectional area |
Approx. overall diameter |
Approx. mass |
Calculated D.C. resistance at 20oC |
Calculated breaking load |
Al |
Steel |
mm2 |
No./mm |
mm2 |
mm2 |
mm |
kg/km |
Ω/km |
kN |
RABBIT |
50 |
6/3.35 |
1/3.35 |
52.88 |
61.7 |
10.05 |
214 |
0.5426 |
18.35 |
DOG |
100 |
6/4.72 |
7/1.57 |
105 |
118.5 |
14.15 |
394 |
0.2733 |
32.7 |
WOLF |
150 |
30/2.59 |
7/2.59 |
158.1 |
194.9 |
18.13 |
726 |
0.1828 |
69.2 |
DINGO |
150 |
18/3.35 |
1/3.35 |
158.7 |
167.5 |
16.75 |
506 |
0.1815 |
35.7 |
LYNX |
175 |
30/2.79 |
7/2.79 |
183.4 |
226.2 |
19.53 |
842 |
0.1576 |
79.8 |
ZEBRA |
400 |
54/3.18 |
7/3.18 |
428.9 |
484.5 |
28.62 |
1621 |
0.0674 |
131.9 |