• Flat Rubber Cable Copper Elevator Cable
  • Flat Rubber Cable Copper Elevator Cable
  • Flat Rubber Cable Copper Elevator Cable
  • Flat Rubber Cable Copper Elevator Cable
  • Flat Rubber Cable Copper Elevator Cable
  • Flat Rubber Cable Copper Elevator Cable

Flat Rubber Cable Copper Elevator Cable

Type: Insulated
Conductor Type: Stranded
Application: Underwater, Portable, Mining
Conductor Material: Copper
Sheath Material: Rubber
Insulation Material: Rubber
Samples:
US$ 0.01/Piece 1 Piece(Min.Order)
| Request Sample
Customization:

360° Virtual Tour

Diamond Member Since 2009

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
Elevator Cable
Material Shape
Flat Wire
Range of Application
Elevator
Certification
ISO9001, CE, CCC, RoHS, VDE
Brand
Yiang Cable
Insulation
Rubber, TPE, Silicone Rubber, Epr
Size
1.5, 2.5, 4, 6, 10....240
Transport Package
Drum, Steel Drum
Specification
70 50
Trademark
Yifang cable
Origin
Henan Zhengzhou
HS Code
8544492100
Production Capacity
20000km/Year

Product Description

Flat Rubber Cable Copper Elevator Cable

APPLICATION:

Rubber insulated and sheathed cables are suitable for both indoor and outdoor use in industrial and agricultural plant and on constuction sites. Flexible cables are also suitable for areas of medium mechanical stress and can be used in hot, cold, damp environments or in temporary immersion in water. They are also oil resistant.

CONSTRUCTION:

Conductors: Flexible plain copper wire / flexible tinned copper wire.

Insulation: Rubber / EPR rubber.

Metal screened layer: Tinned copper wire braiding shield

SHEATH: Synthetic Rubber / neoprene rubber.

MINIMUM BENDING RADIUS: Upto 25mm2 6D

MAXIMUM CONDUCTOR TEMPERATURE: 60° C.

CURRENT RATING:

<4mm2 Table 4H3A, 4H3B in BS 7671 or on page 103
>4mm2 Table 4H1A in BS 7671

Properties
Special rubber outer sheath, cold-resistant
Extensively oil resistant, oil-/ chemical Resistance - see table Technical Informations
Extremely small bending radius
High flexibility
Minimum waste of space
Packeting possibility
Behaviour in fire: 
Test according to VDE 0482-332-1-2, DIN EN 60332-1-2/ IEC 60332- 
TVVB (Parallel) free suspension length must not exceed 35 meters, and the lift speed 1.6m/s.
TVVB(interwist) free suspension length must not exceed 80 meters, and the life speed must not exceed 4m/s.
 
Elevator Cable Type  
H05VVH6-F 300/500V (2-60)X(0.5-1.0) H05VVD3H6-F 300/500V (2-60)X(0.5-1.0)
H05V2V2H6-F 300/500V (2-60)X(0.5-1.0) H05V2V2D3H6-F 300/500V (2-60)X(0.5-1.0)
H05V3V3H6-F 300/500V (2-60)X(0.5-1.0) H05V3V3D3H6-F 300/500V (2-60)X(0.5-1.0)
H07VVH6-F 450/750V (3-12core)X(1.5-2.5) H07VVH6-F 450/750V (4-5core)X(4.0-16.0)
H07VVH6-F 450/750V (4-5core)X(25.0-70) H07VVD3H6-F 450/750V (3-12core)X(1.5-2.5)
H07VVD3H6-F 450/750V (4-5core)X(4.0-16.0) H07VVD3H6-F 450/750V (4-5core)X(25.0-70)
H07V2V2H6-F 450/750V (3-12core)X(1.5-2.5) H07V2V2H6-F 450/750V (4-5core)X(4.0-16.0)
H07V2V2H6-F 450/750V (4-5core)X(25.0-75) H07V2V2D3H6-F 450/750V (3-12core)X(1.5-2.5)
H07V2V2D3H6-F 450/750V (4-5core)X(4.0-16.0) H07V2V2D3H6-F 450/750V (4-5core)X(25.0-70)
H07V3V3H6-F 450/750V (3-12core)X(1.5-2.5) H07V3V3H6-F 450/750V (4-5core)X(4.0-16.0)
H07V3V3H6-F 450/750V (4-5core)X(25.0-75) H07V3V3D3H6-F 450/750V (3-12core)X(1.5-2.5)
H07V3V3D3H6-F 450/750V (4-5core)X(4.0-16.0) H07V3V3D3H6-F 450/750V (4-5core)X(25.0-70)
H05 Z1Z1H6-F 300/500V (2-60)X(0.5-1.0) H05 Z1Z1D3H6-F 300/500V (2-60)X(0.5-1.0)
H07 Z1Z1H6-F 300/500V (3-12core)X(1.5-2.5) H07 Z1Z1H6-F 300/500V (4-5core)X(4.0-16.0)
H07 Z1Z1H6-F 300/500V (4-5core)X(25.0-70) H07 Z1Z1D3H6-F 300/500V (3-12core)X(1.5-2.5)
H07 Z1Z1D3H6-F 300/500V (4-5core)X(4.0-16.0) H07 Z1Z1D3H6-F 300/500V (4-5core)X(25.0-70)
 
Cable Parameter
AWG No. of Cores x Nominal Cross Sectional Area # x mm² Nominal Thickness of Insulation mm Nominal Thickness of Sheath mm Nominal Overall Diameter mm Nominal Copper Weightkg/Km Nominal Weightkg/Km
H05VVH6-F
18(24/32) 4 x 0.75 1.2 0.6 4.2 x 12.6 29 90
18(24/32) 8x 0.75 1.2 0.6 4.2 x 23.2 58 175
18(24/32) 12x 0.75 1.2 0.6 4.2 x 33.8 86 260
18(24/32) 18x 0.75 1.2 0.6 4.2 x 50.2 130 380
18(24/32) 24x 0.75 1.2 0.6 4.2 x 65.6 172 490
17(32/32) 4 x 1.00 1.4 0.7 4.4 x 13.4 38 105
17(32/32) 5×1.00 1.4 0.7 4.4 x 15.5 48 120
17(32/32) 8 x 1.00 1.4 0.7 4.4 x 24.8 77 205
17(32/32) 12x 1.00 1.4 0.7 4.4 x 36.2 115 300
17(32/32) 18x 1.00 1.4 0.7 4.4 x 53.8 208 45
17(32/32) 24x 1.00 1.4 0.7 4.4 x 70.4 230 590
H07VVH6-F
16(30/30) 4 x1.5 1.5 0.8 5.1 x 14.8 130 58
16(30/30) 5 x1.5 1.5 0.8 5.1 x 17.7 158 72
16(30/30) 7 x1.5 1.5 0.8 5.1 x 25.2 223 101
16(30/30) 8 x1.5 1.5 0.8 5.1 x 27.3 245 115
16(30/30) 10 x1.5 1.5 0.8 5.1 x 33.9 304 144
16(30/30) 12 x1.5 1.5 0.8 5.1 x 40.5 365 173
16(30/30) 18 x1.5 1.5 0.8 6.1 x 61.4 628 259
16(30/30) 24 x1.5 1.5 0.8 5.1 x 83.0 820 346
14(30/50) 4 x2.5 1.9 0.8 5.8 x 18.1 192 96
14(30/50) 5 x2.5 1.9 0.8 5.8 x 21.6 248 120
14(30/50) 7 x2.5 1.9 0.8 5.8 x 31.7 336 168
14(30/50) 8 x2.5 1.9 0.8 5.8 x 33.7 368 192
14(30/50) 10 x2.5 1.9 0.8 5.8 x 42.6 515 240
14(30/50) 12 x2.5 1.9 0.8 5.8 x 49.5 545 288
14(30/50) 24 x2.5 1.9 0.8 5.8 x 102.0 1220 480
12(56/28) 4 x4 2.5 0.8 6.7 x 20.1 154 271
12(56/28) 5 x4 2.5 0.8 6.9 x 26.0 192 280
12(56/28) 7 x4 2.5 0.8 6.7 x 35.5 269 475
10(84/28) 4 x6 3.0 0.8 7.2 x 22.4 230 359
10(84/28) 5 x6 3.0 0.8 7.4 x 31.0 288 530
10(84/28) 7 x6 3.0 0.8 7.4 x 43.0 403 750
8(80/26) 4 x10 4.0 1.0 9.2 x 28.7 384 707
8(80/26) 5 x10 4.0 1.0 11.0 x 37.5 480 1120
6(128/26) 4 x16 5.6 1.0 11.1 x 35.1 614 838
6(128/26) 5 x16 5.6 1.0 11.2 x 43.5 768 1180
 
 
Specification
 
Type Voltage calss Core×Section Thick of insulation Thick of Sheath Insulation resistance at 70°C Ctor DC resi at 20°C Size Ref Weight
(mm2) (mm) (mm) (MΩ·km) (Ω/km) (mm) (kg/km)
    e1 e2 e3        
TVVB 30×0.75 0.4 2 1.2 1.4 ≥0.011 ≤26.0 41.0×9.0 640
300/500V 36×0.75 0.4 2 1.2 1.4 ≥0.011 ≤26.0 45.0×9.5 775
  40×0.75 0.4 2 1.2 1.4 ≥0.011 ≤26.0 52.5×9.0 840
  42×0.75 0.4 2 1.2 1.4 ≥0.011 ≤26.0 51.0×9.5 900
  48×0.75 0.4 2 1.2 1.4 ≥0.011 ≤26.0 57.0×9.5 1010
  60×0.75 0.4 2 1.2 1.4 ≥0.011 ≤26.0 69.0×9.5 1250
TVVB 30×1.0 0.6 2 1.4 1.6 ≥0.010 ≤19.5 49.0×10.5 900
300/500V   36×1.0 0.6 2 1.4 1.6 ≥0.010 ≤19.5 54.0×11.5 1050
  40×1.0 0.6 2 1.4 1.6 ≥0.010 ≤19.5 63.0×10.5 1150
  42×1.0 0.6 2 1.4 1.6 ≥0.010 ≤19.5 61.0×11.5 1100
  48×1.0 0.6 2 1.4 1.6 ≥0.010 ≤19.5 69.0×11.5 1350
  60×1.0 0.6 2 1.4 1.6 ≥0.010 ≤19.5 84.0×11.5 1690 
   
Normal
Cross-Sectional
Area mm2
No./mm Insulation Thickness Overall Diameter DC Resistance
at 20 °C Ohm/km
500V 1000V 500V 1000V Copper Tinned Copper
0.12 7/0.15 0.6 0.8 1.65 2.05 150 163
0.2 12/0.15 0.6 0.8 1.8 2.2 92.3 96
0.3 16/0.15 0.6 0.8 1.9 2.3 69.2 71.2
0.4 23/0.15 0.8 1.0 2.4 2.8 48.2 49.6
0.5 16/0.2 0.8 1.0 2.53 2.93 39 40.1
0.75 24/0.2 1.0 1.2 3.14 3.54 26 26.7
1.0 32/0.2 1.0 1.2 3.32 3.72 19.5 20.2
1.5 30/0.25 1.0 1.2 3.60 4.00 13.3 13.7
2 40/0.25 1.0 1.2 3.84 4.24 9.6 9.9
2.5 49/0.25 1.0 1.2 4.0 4.4 7.98 8.21
4.0 56/0.3 1.2 1.4 5.0 5.4 4.95 5.09
6 84/0.3 1.2 1.4 6.0 6.4 3.3 3.39
10 84/0.4 1.4 1.6 7.4 7.8 1.91 1.95
16 126/0.4 1.4 1.6 8.5 8.9 1.21 1.24
25 196/0.4 1.6 1.8 10.3 10.7 0.78 0.795
35 276/0.4 1.8 2.0 12.1 12.5 0.554 0.565
50 396/0.4 2.0 2.2 14.3 14.7 0.386 0.939
70 360/0.5 2.0 2.2 16.4 16.8 0.272 0.277
95 475/0.5 2.2 2.4 18.9 19.3 0.206 0.210
120 608/0.5 2.2 2.4 20.4 20.8 0.161 0.164
 
china traveling cable  Specification:
Type Cores Cross Section Width (mm) Thickness(mm) Weight (kg/km) Cable Shape
TVVB 2 0.75 8.0±1.0 4.2±0.5 68 Parallel
TVVB 3 0.75 10.4±1.0 4.2±0.5 90 Parallel
TVVB 4 0.75 13.7±1.0 4.2±0.5 118 Parallel
TVVB 5 0.75 17.1±1.0 4.2±0.5 145 Parallel
TVVB 6 0.75 19.4±1.0 4.2±0.5 167 Parallel
TVVB 7 0.75 21.8±1.5 4.2±0.5 188 Parallel
TVVB 8 0.75 24.1±1.5 4.2±0.5 210 Parallel
TVVB 9 0.75 26.5±1.5 4.2±0.5 231 Parallel
TVVB 10 0.75 28.8±1.5 4.2±0.5 253 Parallel
TVVB 11 0.75 31.2±2.0 4.2±0.5 274 Parallel
TVVB 12 0.75 33.5±2.0 4.2±0.5 277 Parallel
TVVB 13 0.75 35.9±2.0 4.2±0.5 298 Parallel
TVVB 14 0.75 39.2±2.0 4.2±0.5 323 Parallel
TVVB 15 0.75 41.6±2.0 4.2±0.5 344 Parallel
TVVB 16 0.75 43.9±2.0 4.2±0.5 364 Parallel
TVVB 17 0.75 46.3±2.0 4.2±0.5 384 Parallel
TVVB 18 0.75 49.6±2.0 4.2±0.5 410 Parallel
TVVB 19 0.75 52.0±2.0 4.2±0.5 430 Parallel
TVVB 20 0.75 54.3±2.0 4.2±0.5 450 Parallel
TVVB 21 0.75 56.7±2.0 4.2±0.5 470 Parallel
TVVB 22 0.75 59.0±2.0 4.2±0.5 491 Parallel
TVVB 23 0.75 61.4±2.5 4.2±0.5 511 Parallel
TVVB 24 0.75 64.7±2.5 4.2±0.5 537 Parallel
TVVB 24 0.75 31.3±2.0 8.4±0.5 470 Bunch Core
TVVB 30 0.75 39.9±2.0 7.8±0.5 582 Bunch Core
TVVB 36 0.75 43.5±2.0 8.4±0.5 691 Bunch Core
TVVB 40 0.75 50.7±2.0 7.8±0.5 748 Bunch Core
TVVB 42 0.75 49.5±2.0 8.4±0.5 791 Bunch Core
TVVB 48 0.75 55.5±2.0 8.4±0.5 891 Bunch Core
TVVB 54 0.75 61.5±2.5 8.4±0.5 990 Bunch Core
TVVB 60 0.75 67.5±2.5 8.4±0.5 1090 Bunch Core
TVVB 66 0.75 73.5±2.5 8.4±0.5 1190 Bunch Core
Flat Rubber Cable Copper Elevator Cable
Flat Rubber Cable Copper Elevator Cable
Flat Rubber Cable Copper Elevator Cable
Our company

Yifang Electric group mainly specialized in wire&cables,including designment,production and sale.

Products are mainly covering low,medium,high voltage(1KV to 220KV) XLPE Insulated power cable,PVC insulated power cable,ABC cable,building cable control cable,rubber cable welding cable Etc.

Our XLPE cable can be manufactured according to the company's specification which is equivalent to IEC 60502,IEC60332,IEC60754. Some indexes are superior to above international standard.


Flat Rubber Cable Copper Elevator Cable
Our certificate

Flat Rubber Cable Copper Elevator Cable

FAQ

1.Q:Are you a factory or trading company? 
 A: Manufacturing base in Henan ,China, with more than 500 workers.

2.Q:How can I visit there? 
 A: Sure,If you need,we will arrange the driver to pick you up. 

3.Q:How can I get some samples? 
 A: Contact me on below,Determin sample and address for shipping.  

4.Q:Have you ever supplied cables to our country? 
 A: Yifang Cables have been sold to over 100 countries and regions in the world. can you contact me for details.

5.Q:What is your MOQ? 
A: MOQ Normally 500 meters for big diameter cables.Please contact me for detail info if you have specific cable requirement. 

6. Q:When can I get the price? 
A: Usually quote within 6 hours after we get your inquiry. 

7.Q:How long is your delivery time?
 A: According to your order's quantity.Usually our lead time is 3 - 20 working days.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2009

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
122
Year of Establishment
2001-02-22